| RFB-112-26 Parks – EP Tom Sawyer-Pool and Recreational Bldg Upgrades | 
RFB-112-26 Parks – EP Tom Sawyer-Pool and Recreational Bldg Upgrades
Estimate:
$1,665,279.00
Estimated Length of Project:
120 (Substantial Completion) + 30 (Final Completion)
This project provides for the renovation of the existing men’s and women’s restrooms and locker rooms at E.P. Tom Sawyer State Park Pool and Recreation facility, Louisville KY
The work scope will involve the following features:
• Renovation of men’s and women’s restrooms on the main level.
• Renovation of men’s and women’s locker room facilities.
• Removal and replacement of all plumbing fixtures, faucets, flush valves, hangers and supports, floor drains and related accessories.
• Removal and replacement of all waste and vent piping including all underground sanitary waste and vent piping.
• Removal and replacement of all domestic hot, cold and hot water return piping including water heaters and main service backflow preventer.
• Provide trench drain covers for the existing drain troughs.
• Preparation of flooring for new resinous flooring.
• Preparation of walls in the restrooms and locker rooms for new paint.
• Removal and replacement of existing ceilings in the restrooms and locker rooms. New ceilings in the locker room areas will be moisture resistant lay-in type.
• Providing new ADA casework, shrouds and undermount lavatories for restrooms and locker rooms.
• Construction of new block walls to separate shower stalls in the Men’s shower room.
• Provide power for mechanical equipment and plumbing water heaters and associated equipment.
• Demo existing light fixtures and reuse existing power circuits for new lighting fixtures in newly remodeled areas.
• Demo existing receptacles and reuse existing power circuits for newly installed receptacles in newly remodeled areas.
• Add new power for hand dryers as required.
• Modify existing power panels as required for new mechanical/plumbing equipment.
• Remove existing locker room/restroom energy recovery ventilator DX cooling coil, remote air-cooled condensing unit, refrigerant piping, condensate drain piping, electronic controls.
• Provide new duct-mounted DX heat pump coil, refrigerant heat recovery dehumidification coil, refrigerant piping, condensate drain piping, remote air-cooled heat recovery heat pump, and direct digital controls for locker room/restroom HVAC.
Project Location: Louisville